 ROUGH OPENING REQUIREMENTS
 
 1. EXTERIOR FRAMES
 2. POCKET FRAMES *Frame opening 2" over double call out size in width and 4" over call out size in height
 
              
              | 
                  
                    |  | (1) Example: Single 2/6 x 6/8 opening - R.O. should be 62" w. x 84" h. |  
                    |  | (2) Example: Double 2/6 x 6/8 opening - R.O. should be 122" w. x 84" h |  |  3. METAL FRAMES
 4. INTERIOR PREFITS
 5. WARDROBE SLIDING BYPASS OPENINGS (with 1/2" drywall wrapped)
 
            
              | A) 6/8 Units with 2 doorsFrame opening at call out size in width and 2” over call out in height
 |  
              | 
                  
                    |  | (1) Example: 2-door 8/0 x 6/8 opening – R.O. should be 96” w. x 82” h. |  |  
              |  |  
            
              | B) 6/8 Units with 3 doorsFrame opening 1” under call out size in width and 2” over call out in height
 |  
              | 
                  
                    |  | (1) Example: 3-door 12/0 x 6/8 opening – R.O. should be 143” w. x 82” h. |  |  
              |  |  
            
              | C) 8/0 Units with 2 doorsFrame opening at call out size in width and 3/4” over call out in height
 |  
              | 
                  
                    |  | (1) Example:  2-door 8/0 x 8/0 opening – R.O. should be 96” w. x 96-3/4” h. |  |  
              |  |  
            
              | D) 8/0 Units with 3 doorsFrame opening  1” under call out size in width and 3/4” over call out in height
 |  
              | 
                  
                    |  | (1)  Example: 3-door 12/0 x 8/0 opening – R.O. should be 143” w. x 96-3/4” h. |  |  
              |  |  
            
              |  **NOTE**For 8' ceiling height - 8' high openings should be framed at ceiling height and have continuous backing.
 |  
              |  |  
              |  |  6. BIFOLD OPENING (with 1/2" drywall wrapped)
 **NOTE**8' high openings should be framed at ceiling height and have continuous backing.
 
 7. MEDICINE CABINETS
 For openings with 26” mirrors frame 14” x 24” x 3-1/2”
 For openings with 36” mirrors frame 14” x 34” x 3-1/2”
 **NOTE: YOU MUST BE ABLE TO VERIFY THAT SHEAR PANEL IS COMPLETE FOR ALL UNITS SCHEDULED PRIOR TO RECEIVING EXTERIOR JAMB DELIVERY AND INSTALLATION.
   |